PO BOX 1654 97075-1654 8687 SW HALL BLVD BEAVERTON, OREGON FAX 503.646.3903
LIT | AEI MODEL | PRODUCT | DESCRIPTION | MOUNTING | CIRCUITS |
---|---|---|---|---|---|
|
1220 (47060002) | 600 OHM CLIP (SOLDER) | The Terminating Clip is a film resistor mounted on ceramic substrate with two tin-plated beryllium-copper connectors which allow 600 ohm termination. The minature clip-ons fasten directly to solder terminal equipped 211AF-8" terminal blocks. Jumpering, soldering, wire-wrapping and other separate blocks are eliminated. The unit is reusable. | MTG | 1 pos. |
|
1221 (47061001) | 600 OHM CLIP (WIRE-WRAP) | The Terminating Clip is a film resistor mounted on ceramic substrate with two tin-plated beryllium-copper connectors which allow 600 ohm termination. The minature clip-ons fasten directly to wire-wrap terminal equipped 211AL-8" terminal blocks. Jumpering, soldering, wire-wrapping and other separate blocks are eliminated. The unit is reusable. | MTG | 1 pos. |
|
1224 | 600 OHM RESISTOR BLOCK | These precision, 1% tolerance, metal-film resistors are mounted on a
211AL-8" terminal block. The resistors are a convenient method of
terminating unused legs on frame mounted bridges. One hundred (100) circuits per block. |
211AL-8" BLK | 100 pos. |
|
1230 | TERMINATING RESISTORS | These precision, 1% tolerance, metal-film resistors are mounted on a 89F1F-100 type terminal block. The resistors are a convenient method of terminating unused legs on frame mounted bridges. One hundred (100) circuits per block. 600 ohm configuration. | 89F1F-100 BLK | 100 pos. |
|
2010 | NOTCH FILTER CARD | The Card is used to cancel transmission frequency bands. (The Card is used in Model 9060 Horizontal Mounting Shelves.) | CARD | 1 pos. |
|
3030 | E & M APPLIQUE | E & M Appliques interface between office trunks equipped with Type II E & M signaling and signaling circuits equipped with Type I E & M signaling (or between Type III and Type I signaling circuits.) 211AL-8" terminal block utilized. -48VDC power. Twelve (12) circuits per block. | 211AL-8" BLK | 12 pos. |
|
3058 | CIRCUIT BREAKER PANEL | The Circuit Breaker Panel provides individual over-current protected 120VAC power. Eight (8) magnetic circuit breakers (on front of panel) allow individual protection for each power connector. The panel set up allows for uninterrupted operation of remaining power outlets. Commonly used to protect additional 120VAC power requirements in the same or adjacent mounting racks. | 19" / 23" PNL | 8 pos. |
|
3201 | TRANSFORMER MOUNTING PANEL | Panel (model 3201) accepts twenty-four (24) cards (model 3201A). 6600 ohm to 600 ohm transformers are mounted on PCB cards which plug into edge connectors on the panel. Input / output is via 25-pair connector on the rear of the panel. Primary impedance: 6600 ohms. Secondary impedance: 600 ohms. Unit mounts in 19" and 23" rack. | 19" / 23" PNL | 24 pos. |
|
3201A | TRANSFORMER MOUNTING CARD | Panel (model 3201) accepts twenty-four (24) cards (model 3201A). 6600 ohm to 600 ohm transformers are mounted on PCB cards which plug into edge connectors on the panel. Input / output is via 25-pair connector on the rear of the panel. Primary impedance: 6600 ohms. Secondary impedance: 600 ohms. Unit mounts in 19" and 23" rack. | CARD | 1 pos. |
|
5030 | JACK PANEL | The Jack Panel utilizes break, test, and monitor Bantam jacks wired to 25-pair connectors mounted on the rear of the panel for input / output. Sixteen (16) circuits per panel. Bantam jacks for DEMOD, MOD, EQ IN, EQ OUT, and MONITOR. | 19" / 23" PNL | 16 pos. |
|
5031 | JACK PANEL w/ HYBRIDS | Eight (8) transformers (2 per circuit) mounted on removable PCB cards, four (4) cards per panel, for a total of sixteen (16) circuits. Bantam jacks on front of panel for DEMOD, MOD, EQ IN, EQ OUT, and MONITOR wired to 25-pair connectors on rear of panel for input / output. | 19" / 23" PNL | 16 pos. |
|
8050 | FIBRE OPTIC MODEM SHELF | Twelve (12) ST Connector Couplings are centrally mounted within the shelf unit. Panel cut-outs on the base and both sides allow access to the ST Connectors. Mounts in 19" and 23" racks. | 19" / 23" PNL | 12 pos. |
|
8051 | FIBRE OPTIC PATCH SHELF | Twelve (12) Female to Female Gender Changers are centrally mounted within the shelf unit. Panel cut-outs on the base and both sides allow access to the Gender Changers. Mounts in 19" and 23" racks. | 19" / 23" PNL | 12 pos. |
|
8052 | 6 PORT RS-232 DATA COMBINER | The Data Combiner allows up to six (6) DTE devices to be connected to a common DCE device such as a modem. Packaged on a 19" aluminum panel to allow for relay rack mounting. | 19" PNL | 6 pos. |
|
8053 | CUTOVER MOUNTING BLOCK | DPDT transfer switches. Intended for low level dry circuit voice frequency switching. (no DC) Gold plated contacts are standard. | 211AL-8" BLK | na |
|
8056 | RS-232 / V.35 RATE ADAPTER | The unit is used in LAN-WAN connectivity, video conferencing and other high speed applications where one vendor's DCE is required to communicate with another vendor's DTE. The unit is DCE / DTE switchable allowing a V.35 host to interface with a synchronous RS-232 modem or a synchronous RS-232 terminal to talk to a V.35 CSU / DSU. | 19" PNL | na |
|
8057 | DTMF CAMERA CONTROLLER | The Controller recieves DTMF telephony tones and translates your commands to various visual and audio monitoring equipment. The commands can operate cameras, lenses, pan-n-tilts, tape recorders, video cassette recorders (VCRs), camcorders, etc. The command tones can be intialed to the controller on site, remotely from short distances, or a base station. | UNIT | na |
|
8060 | BREAK OUT BOX | Front panel female RS-232 connectors are wired to rear panel male connectors as well as a 80-pin connector ribbon connector. Used in RS-232 signal distribution applications. Sixteen (16) circuits, 19" / 23" rack mounting. | 19" / 23" PNL | 16 pos. |
|
8062 | CURRENT LIMITER BLOCK | Used in current limiting applications, the Current Limiter block consists of each circuit having two (2) resistors in series on the RING and TIP leads. Resistors are 150 ohm, 1W, 5% MOF. Fifty (50) circuits, 211AL-8" terminal block, wire-wrap terminals. | 211AL-8" BLK | 50 pos. |
|
8063 | ACCESSORY SWITCH | Allows personal computer operator to switch easily between a mouse and a trackball by merely using the switch on the unit. There is no need to plug / unplug the cables from the computer while choosing between the two. | UNIT | na |
|
8065 | AUDIO / VIDEO SWITCH | This unit enables the operator to input up to three (3) audio and three (3) video units and switch between the three (3) audio and three (3) video inputs to one (1) audio output and one (1) video output locally using common DTMF dialing tones or the switches on the unit. | UNIT | na |
|
8066 | DTMF SINGLE CAMERA CONTROLLER | The Single Camera Controller enables an operator to control a single camera from a remote site or locally using common DTMF dialing tones. The unit controls one Pan-n-Tilt and one Lens, and two 12VDC power outputs. Input power is 12VDC. Interconnect cables are supplied. | UNIT | na |
|
8069 | CAMERA MOUNTING ASSEMBLY MECHANISM | When using a surveillance camera with a standard pan-n-tilt, a large pan and tilt aperature is needed to allow camera viewing operation. thus allowing the operator greater flexibility in hiding the surveillance camera and related support equipment. | UNIT | na |
|
8070 | CUTOVER BLOCK | 4PDT transfer switches. Intended for low level dry circuit voice frequency switching. (no DC) Gold plated contacts are standard. | 211AL-8" BLK | x |
|
8103 | TELCO PATCH PANEL (RJ48X) | The Telco Patch Panel provides fast, flexible access for voice and data circuits. This unit allows for the easy patching of telephone and data communications lines utilizing RJ48X conductor jacks for use with six (6) or eight (8) wire systems. Fourteen (14) RJ48X jacks, mounted on the front of the panel, are wired to wire-wrap pins, mounted on the rear of the panel, for input/output connections. | 19" / 23" PNL | 14 pos. |
|
9059 | TELEMETRY SHELF | Consisting of a customer provided telemetry shelf, and AEI model 3057 Fuse Panel, and three (3) cross connect connectorized panels, this unit is mechanically assembled into a single rack mount unit and wired to customer specifications. Applications include alarm reporting and information distribution. | 19" / 23" PNL | x |
|
9060 | HORIZONTAL MOUNTING SHELF | The Shelf accepts two (2) Model 2010 Notch Filter Cards for a total of sixteen (16) circuits. Input / Output is via 25-pair telco connectors, Input-male, Output-female. | 19" / 23" PNL | 16 pos. |