PO BOX 1654 97075-1654 8687 SW HALL BLVD BEAVERTON, OREGON FAX 503.646.3903
Model 91062 Alarm Annunciator Panel Model 91055-002 Alarm Extension Panel Model 91060-021 Alarm Interface Panel
Accurate Electronics Inc.'s Alarm Annunciator System monitors up to sixty-four (64) separate alarms
(or more with an Extension Panel). The system provides visual, audible, and remote indication of alarm status.
The alarm equipment is designed for use as a stand-alone system or as an
enhancement to a computer controlled alarm surveillance system.
|
|||||
---|---|---|---|---|---|
ALARM ANNUNCIATOR PRODUCTS |
|||||
LIT | AEI MODEL | PRODUCT | DESCRIPTION | MOUNTING | CIRCUITS |
|
91062-001 | ALARM ANNUNCIATOR PANEL WITH RELAYS |
-24VDC. (previously 91062-L1) The Alarm Annunciator Panel (Indication Unit), it provides a LED display for visual alarm indication and has 25-pair connectors for wiring to the Interface Panel. The unit operates in two modes (LOCal and REMote) and provides system control functions. It also provides an audible alarm indication that can be connected to the house alarm. Sixty-four (64) alarms are monitored. |
19" / 23" PNL | 64 pos. |
|
91062-002 |
ALARM ANNUNCIATOR PANEL WITHOUT RELAYS |
-24VDC. (previously 91062-L2) The Alarm Annunciator Panel (Indication Unit), it provides a LED display for visual alarm indication and has 25-pair connectors for wiring to the Interface Panel. The unit operates in two modes (LOCal and REMote) and provides system control functions. It also provides an audible alarm indication that can be connected to the house alarm. Sixty-four (64) alarms are monitored. |
19" / 23" PNL | 64 pos. |
|
91064-001 |
ALARM ANNUNCIATOR PANEL WITH RELAYS |
-48VDC. (previously 91064-L1) The Alarm Annunciator Panel (Indication Unit), it provides a LED display for visual alarm indication and has 25-pair connectors for wiring to the Interface Panel. The unit operates in two modes (LOCal and REMote) and provides system control functions. It also provides an audible alarm indication that can be connected to the house alarm. Sixty-four (64) alarms are monitored. |
19" / 23" PNL | 64 pos. |
|
91064-002 |
ALARM ANNUNCIATOR PANEL WITHOUT RELAYS |
-48VDC. (previously 91064-L2) The Alarm Annunciator Panel (Indication Unit), it provides a LED display for visual alarm indication and has 25-pair connectors for wiring to the Interface Panel. The unit operates in two modes (LOCal and REMote) and provides system control functions. It also provides an audible alarm indication that can be connected to the house alarm. Sixty-four (64) alarms are monitored. |
19" / 23" PNL | 64 pos. |
|
91055-002 | ALARM EXTENTION PANEL WITHOUT RELAYS |
(previously 91055-L2). This unit connects through the Interface Panel to the Alarm Annunciator Panel to extend its alarm capacity. It provides an LED display for visual indication of alam status and indicates one front panel LED for power indication and one push button for LED TST. One or more Extension Panel / Interface Panel sets can be connected in daisy-chain fashion. | 19" /23" PNL | 64 pos. |
|
91060-021 | ALARM INTERFACE PANEL | (previously 91055-L2-L2). This unit is a convenient terminal field for wiring. It has 25-pair connectors for interfacing to an Extension Panel or Annunciator Panel, and to central monitoring system wiring. | 19" / 23" PNL | 64 pos. |
|
91058 | CABLE | UNIT | na | |
|
91059 | CABLE | UNIT | na | |
|
91070 | ALARM ACCESSORY SHELF | The shelf is a card cage that accepts Models 91075, 91076, and 91079. These units are used to condition alarm sugnals for the Alarm Annunciator System. The shelf accepts a maximum of twenty-one (21) cards, allowing for any combination of cards. It requires no power or ground connections. | 19" / 23" PNL | 21 max |
|
91075 | ALARM CONCENTRATOR CARD | The Alarm Concentrator Card merges a number of alarm inputs to provide one alarm output signal (ground) when any one or more of the alarm input signals is "on" (grounded). Alarm inputs are concentrated in basic groups, each having one alarm. Switches on the card allow joining groups together. Closing all switches connects all inputs together. Forty (40) inputs, one to ten (1-10) outputs. | CARD | na |
|
91076 | ALARM TIME DELAY CARD | The Alarm Time Delay Card is used to block short duration alarms. An alarm must be continuously active for a preselected time period before it will be passed to the Alarm Annunciator Panel. | CARD | na |
|
91079 | BATTERY to GROUND CONVERTER CARD | The Battery to Ground Converter Card accepts alarm signals at battery potential and outputs alarm signals at ground potential. The required connector and its mounting hardware are included with the card. Wiring is connected to wire-wrap terminals on the connector. Each circuit requires one input and one output connection. | CARD | na |